ITC Series for Conductor Splicing & Taps

Pre-Insulated Multi-Tap Connectors

DAIER supplies ITC pre-insulated splice and multi-tap connectors for copper and aluminum wiring. Compare inline, single-sided and dual-sided entry layouts with 2-, 3- and 4-port options. Match the conductor range, connection layout and installation requirements to the exact ordering code.

Pre-Insulated Multi-Tap Connectors
  • Entry Layouts Inline, Single & Dual
  • Port Options 2, 3 & 4 Ports
  • Conductor Options Copper & Aluminum
  • Connection Type Insulated Set-Screw

ITC Splice & Multi-Tap Connector Models

ITC-103D-4/0AWG 250 MCM – 6 AWG 3 Port Dual-Sided Entry Pre-insulated Multi-tap Connector

The 3 port dual entry pre-insulated multi-tap connector is expertly designed to securely accommodate a wide range of wire gauges, from 250 MCM - 6 AWG.

ITC-103D-3/0AWG 3/0 AWG – 6 AWG 3 Port Dual Entry Multi-tap Aluminum to Copper Connector

The 3 port dual entry multi-tap aluminum to copper connector is expertly designed to securely accommodate a wide range of wire gauges, from 3/0 AWG - 6 AWG.

ITC-103-2/0AWG 2/0 AWG – 6 AWG 3-Port Single-Sided Entry Insulated Multi-Tap Connector

The 3 port single-side entry insulated multi-tap connector is expertly designed to securely accommodate a wide range of wire gauges, from 2/0 AWG to 6 AWG.

ITC-103D-2/0AWG 2/0 AWG – 6 AWG 3 Ports Dual-Sided Wire Entry Insulated Multi-tap Connector

The 3 port dual-side entry insulated multi-tap connector is expertly designed to securely accommodate a wide range of wire gauges, from 2/0 AWG to 6 AWG.

ITC-103-1/0AWG 1/0 AWG – 14 AWG 3-Port Single-Sided Entry Insulated Multi-Tap Connector

This 1/0 AWG - 14 AWG 3-port single-sided entry insulated multi-tap connector is designed for Aluminum to Copper connections and features an dual-sided entry design.

ITC-103D-1/0AWG 1/0 AWG – 14 AWG 3 Port Dual Entry Pre-Insulated Multi-tap Wire Connector

This 1/0 AWG - 14 AWG 3-port dual-entry pre-insulated multi-tap wire connector is designed for Aluminum to Copper connections.

ITC-103-2AWG 2 AWG – 14 AWG 3-Port Single-Sided Entry Insulated Multi-Tap Connector

This 2 AWG - 14 AWG 3-port single-sided entry insulated multi-tap connector is designed for Aluminum to Copper connections and features an dual-sided entry design.

ITC-103D-2AWG 2 AWG – 14 AWG 3-Port Dual-Sided Entry Insulated Tap Connector

This 2 AWG - 14 AWG 3-Port pre-insulated connector is designed for Aluminum to Copper connections and features an dual-sided entry design.

ITC-103-4AWG 4 AWG – 14 AWG 3 Ports Single-Side Entry Multi-Tap Insulated Connector

The 3 ports single-side entry multi-tap insulated connector is expertly designed to securely accommodate a wide range of wire gauges from 4 AWG to 14 AWG.

ITC-104D-4/0AWG 4 Port Dual Insulated Connector Block | 250 MCM – 6 AWG

  • Capacity : 250MCM to 6 AWG
  • Rating : Dual-Rated AL9CU
  • Ports : 4-Port Dual-Entry

ITC-104-4/0AWG 250 MCM – 6 AWG 4 Port Single-Sided Entry Insulated Multi Tap Connector

This 250 MCM - 6 AWG 4-port pre-insulated multi tap connector is designed for Aluminum to Copper connections and features an single-sided entry design.

ITC-104-3/0AWG 4 Port Insulated Connector Block | 3/0 AWG – 6 AWG

  • Capacity : 3/0 to 6 AWG
  • Rating : Dual-Rated AL9CU
  • Voltage : 600V Max Rating

ITC-104D-3/0AWG 3/0 AWG – 6 AWG 4 Port Dual-Sided Entry Insulated Multi Tap Connector

This 3/0 AWG - 6 AWG 4-port insulated multi tap connector is designed for Aluminum to Copper connections and features an dual-sided entry design.

ITC-104-4AWG 4 AWG – 14 AWG 4 Port Single-Sided Entry Pre-Insulated Multi Tap Connector

This 4 AWG - 14 AWG 4-port pre-insulated multi tap connector is designed for Aluminum to Copper connections and features an single-sided entry design.

Selection Guide

Compare ITC Connectors for Your Wiring Layout

Wire Range & Conductor

  • Match both minimum and maximum wire sizes to the exact specification.
  • Verify copper or aluminum suitability for each conductor.
  • Wire range and voltage rating do not establish load-current capacity.

Ports & Entry Layout

  • ITC-101 inline versions connect wires entering from opposite ends.
  • ITC-102, ITC-103 and ITC-104 versions use single-sided entry; D versions offer dual-sided access.
  • Choose 2, 3 or 4 ports to suit the routing and number of connections.

Fastening & Installation

  • Set-screw connections use model-specific hex or slotted tool sizes.
  • Pre-insulated bodies and port plugs cover the connection areas.
  • Allow cable-bend and tool clearance; request strip-length and torque instructions.

Specification note: Confirm the current drawing and installation requirements for the complete ordering code. Pre-insulation alone does not establish a waterproof rating.

Applications

Typical Pre-Insulated Connector Applications

Use the required conductor range, connection layout and installed protection for each assembly.

Control & Distribution Cabinets

Organize conductor joints and taps within electrical panels, with the specified voltage rating and installation clearances.

Equipment Wiring Assemblies

Select an entry direction and port layout that fits the equipment harness and leaves access for tightening and service.

OEM & Replacement Sourcing

Match the full ordering code, conductor sizes and mechanical drawing for repeat assembly or a like-for-like replacement.

Common Questions

Connector FAQs

Answers about wire fit, entry layouts, insulation and ordering.

For a Project Enquiry

Send the model, wire sizes, conductor materials and quantity.

Send Project Details

Inline splice versions receive wires from opposite ends. Single-sided versions route the entries to one side, while dual-sided versions provide access from either side. Compare the drawing and permitted conductor count; extra openings do not automatically mean extra wire capacity.

Use the minimum and maximum conductor sizes specified for the exact ordering code. Also confirm permitted conductor construction. If the product title and specification table conflict, request the current specification rather than selecting from the model suffix alone.

The published ITC specifications include copper and aluminum conductor compatibility. Confirm the allowed materials and combinations for the quoted model, along with conductor preparation and tightening instructions. Connector body material is a separate specification.

No. The insulation coating and port plugs cover connection areas, but do not by themselves establish an IP rating or approval for wet locations. Specify the exposure conditions and use a suitable enclosure or a documented protected assembly.

Send the part number, wire sizes and conductor materials, required port count and entry layout, system voltage, expected load current and quantity. Include a drawing and any required compliance documents so the exact version can be reviewed.

Share Your Connection Requirements

Send an existing part number, or provide the details below.

Wire Details
Wire sizes and copper/aluminum conductors
Connection Layout
Port count and inline, single- or dual-sided entry
Order Requirements
Quantity, drawing and required documents

Prefer email? sales1@chinadaier.com

Top